Details
YHLO/ COVID-19 Antigen Rapid Test Kit - Nasopharyngeal Swab (1PC)
The GLINE-2019-nCoV Ag assay is a colloidal gold immunoassay for the rapid qualitative determination of nucleocapsid protein of SARS-CoV-2 in nasal swab.
.Efficient, Fast, Reliable and Accurate Testing
.Easy-to-Use, Result in 15 minutes
.Nasal sampling, No special equipment or facilities needed
.Clinically validated sensitivity of 96.38% and specificity of 99.56%
.QR code video manual for easy understanding and usage
.Compliant with EU certificate standards
.Each package box contains one (1) test kit which includes testing cassette, extraction buffer, sampling swab, biohazard sample bag, and instruction for use
Benefits
.Require daily/ regular testing
.Preliminary test person due to environmental/ school/ work needs
.Concern about COVID-19
Product Usage
1. To collect a nasal swab sample, carefully insert the swab into the nostril exhibiting the most visible drainage, or the nostril that is most congested if drainage is not visible. Using gentle rotation, push the swab (about 1.5cm into the nostril). Rotate the swab 5 times or more against the nasal swab wall then slowly remove from the nostril. Using the same swab, repeat sample collection in the other nostril.
2. Peel off the foil film of the extraction tube which contains buffer. Set the extraction tube on the stand hole of the package box.
3. After sample collection, insert the swab into the sample extraction tube, plunge and press the swab tip up and down in the fluid for a minimum of 15 seconds, taking care not to splash contents out of the tube.
4. Remove the swab while squeezing the sides of the tube to extract the liquid from the swab.
5. Press the included dispensing tip onto the extraction tube containing the processed sample. Mix thoroughly by swirling or flicking the bottom of the tube.
6. Invert the extraction tube and hold it vertically. Gently squeeze the ridged body of the tube, dispensing three (3) drops of the processed specimen into the sample well.
7. Read the results which should be ready at 15-20 minutes after adding the processed samples for the sample well. Results read after 20 minutes are invalid.
8. After reading the results, place all the components of the test kit in the provided biohazard sample bag and dispose according to local regulation. Do not reuse any used components.
Storage Condition
Store at 2-30°C. Do not freeze. Avoid direct sunlight.
Warnings
This has been authorized only for the detection of proteins from SARS-COV-2.
Additional Information
SKU | MSDM5555 |
---|